<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-23 10-59-21
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 70 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.2 kHz 63 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 63 kHz 19059 0,6296
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-0,2 dBr 2,88 dBr 5,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 10:59, 23.03.2025
RT
"ELLIMEI, ÖVERI - Miten ihmiset löytä "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 63 kHz MIN: 9 kHz % above 76 kHz: 0,6296 Acquired: 2025/03/23 10.58.17 Total samples: 19059 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,4 dBr MIN: -0,2 dBr AVE: 2,88 dBr % above 12,2 dBr: 0,0 Last value: 4,5 dBr (2025/03/23 10.58.17) 10.44 10.46 10.48 10.50 10.52 10.54 10.56 10.58 0 2 4 6 Pm [dBr]